Indexed metadata

Wearable sensors for prediction of intraamniotic infection in women with preterm premature rupture of membranes: a prospective proof of principle study

Romana Brun, Julia Girsberger, Martina Rothenbühler, Catrin Argyle, Juliane Hutmacher, Christian Haslinger, Brigitte Leeners

Source record

Source: Crossref

Published: Sep 13, 2022

DOI: 10.1007/s00404-022-06753-4

Open original source ↗

Source abstract

Abstract Purpose To evaluate the use of wearable sensors for prediction of intraamniotic infection in pregnant women with PPROM. Materials and methods In a prospective proof of principle study, we included 50 patients diagnosed with PPROM at the University Hospital Zurich between November 2017 and May 2020. Patients were instructed to wear a bracelet during the night, which measures physiological parameters including wrist skin temperature, heart rate, heart rate variability, and breathing rate. A two-way repeated measures ANOVA was performed to evaluate the difference over time of both the wearable device measured parameters and standard clinical monitoring values, such as body temperature, pulse, leucocytes, and C-reactive protein, between women with and without intraamniotic infection. Results Altogether, 23 patients (46%) were diagnosed with intraamniotic infection. Regarding the physiological parameters measured with the bracelet, we observed a significant difference in breathing rate (19 vs 16 per min, P < .01) and heart rate (72 vs 67 beats per min, P = .03) in women with intraamniotic infection compared to those without during the 3 days prior to birth. In parallel to these changes standard clinical monitoring values were significantly different in the intraamniotic infection group compared to women without infection in the 3 days preceding birth. Conclusion Our results suggest that wearable sensors are a promising, noninvasive, patient friendly approach to support the early detection of intraamniotic infection in women with PPROM. However, confirmation of our findings in larger studies is required before implementing this technique in standard clinical management.

Evidence graph

No public relationships recorded yet.

Integrity note: This page is a factual metadata record created by deterministic ingestion. It is not a claim that the work moves a mathematical frontier or has been independently verified.

Wearable sensors for prediction of intraamniotic infection in women with preterm premature rupture of membranes: a prospective proof of principle study — Mathematical Frontier Network