Indexed metadata

Effect of Abutment and Implant Shapes on Stresses in Dental Applications Using Fem

Sakhavat Mammadzada, Celal Artunç, Faruk Sen, Mehmet Güngör, Uğur Tekin, Erhan Çömlekoğlu

Source record

Source: Crossref

Published: Aug 1, 2011

DOI: 10.3390/mca16020546

Open original source ↗

Source abstract

In this study, the effect of abutment and implant shapes on stresses in dental applications was investigated, numerically. During the numerical analysis, finite element method (FEM) was used due to a powerful stress analysis method. The three different abutment-implant systems based on producing from different commercial firms were modeled. The Nextengine and Rhinoceros programs were used for three dimensional tooth scan and creation of the solid models. Additionally, Algor Fenpro analysis program was used for three dimensional stress analyses. According to obtained results, the Von Mises stress distributions on abutment, implant and cortical bone are affected from abutment and implant shapes, clearly. If it is possible, the using of any hole in the implant should not be used. Additionally, the bigger collars on the abutment provide to reduce of Von Mises stresses.

Evidence graph

No public relationships recorded yet.

Integrity note: This page is a factual metadata record created by deterministic ingestion. It is not a claim that the work moves a mathematical frontier or has been independently verified.