PR-471-14207-R02 Field Pump Performance Testing Procedure Phase II Proof of Concept Testing

Fred Robinett

Source record

Source: Crossref

Published: Jun 3, 2018

DOI: 10.55274/r0011491

Open original source ↗

Source abstract

Proof of Concept Testing was performed to verify the Field Pump Performance Testing Procedure developed in Phase I of the project before applying it in the field where costs are higher. Testing was performed in Sulzer's pump test laboratory, in Winterthur Switzerland, using a model pump with similar specific speed and design as used in many crude oil pipeline installations. Testing included a baseline test with water and five tests with mineral oil at viscosities varying from 95 to 500 cSt. To validate field pump performance testing techniques several measurements were taken using different methods as described in the field testing procedure. The various measurements are analyzed for accuracy to assure competent measurements when applied in the field. This work will benefit the liquids pipeline operators by validating the field test procedure prior to actual field testing, thereby providing assurance and acceptance of the methods. Also by completing this study measurement techniques that do not provide accurate results can be identified and eliminated.